2L series steam electromagnetic valve
Special recommendation:(Introduces foreign advanced crafts to produce)

(Usage)
  Suitable for the automatic control of steam, hot water pipelines

(Structure characteristics)
The electromagnetism straightly move diaphragm type structure
The sealed material adopts poly four fluorine ethylene, owns long performance life
The valve core has the conical contour structure, small power when switching on, and fast in speed
Pattern:Always shut down

Technical parameter
Model Type
2L170-10
2L170-15
2L170-20
2L200-25
2L300-35
2L300-40
2L500-50
Fluids used
 steam、hot water
Pattern
 always shut down type
Diameter of flowing hole mm
17
22
30
50
CV VALUE
4.8
7.6
20
48
Diameter of connecting tube
3/8″
1/2″
3/4″
1″
1 1/4″
1 1/2″
2″
Viscid degree of fluids used
Below 20CST
Pressure used kg/cm2
0.5~15
Maximum Durable Pressure kg/cm2
16
Working Temperature ℃
-5~180
Scope of voltage used
±10%
Material of main body
brass